********************* Calibration Procedure ********************* Preparation =========== Make sure you have a well calibrated 1V/Octave CV keyboard available 0V corresponds to C0 2.5V corresponds approx. to F#2 5V corresponds to C5 -5V may not be achieved, in this case your TBD cannot be calibrated for bi-polar CV use Or have a CV generator available which can be adjusted to precise voltages Elektron Analog 4 or ornament and crime work well for this purpose An adjustable lab voltage source together with a precise multimeter does the trick as well Allow for TBD two CV ins to be connected at the same time to the calibration voltage source Procedure ========= In the main menu, hit the “Edit configuration” button to enter the configuration tab Hit the “Reboot, calibrate CVs” button → TBD will reboot in calibration mode, the LED blinks red Turn CV pots all left, apply 0V to CV in jacks → single press trig0 Turn CV pots mid position, apply 2.5V to CV jacks → single press trig0 Turn CV pots all right, apply 5V to CV jacks → single press trig0 Turn CV pots all left, apply -5V to CV in jacks → single press trig0 Turn CV pots mid position, apply 0V to CV in jacks → single press trig0 Turn CV pots all right, apply 5V to CV in jacks → single press trig0 TBD is now calibrated and will reboot to operating mode Backup / Restore ================ You can backup and restore your calibration data e.g. prior to a fresh calibration or system update by hitting the “Calibration Backup” in the Configuration page. A new page will pop up, here you can down/upload calibration data (JSON format). Videos https://www.youtube.com/playlist?list=PLB5iCbhcvJ2qdD7s1o9wsvQ9qtsCUWVLR